Ntrane chiller log sheets pdf

They were eager to get us on board from the start as our reputation precedes us in. Record the date, food items and the time and temperature every hour of the cooling cycle. Water cooled screw chillers mcquay ecoplus data sheet. The commercial chiller inspections app can be used for all types of industrial chillers and commercial refrigeration maintenance needs. Trane rtac 140500 ton units 60 hz user manual page 1. This data comes from in the energyplus reference datasets chillers. Vwr chiller data sheet international equipment trading ltd. We currently provide chiller maintenance, 3 visits a year on 4 air cooled chillers at a secure site.

Continuing the trane commitment to provide the most comprehensive hvac solutions, the series s centravac chiller delivers bestinclass partload efficiencies without compromising fullload efficiency. When touched, the buttons and touch targets open other screens that provide more information and control access. Central building cooling options include water chillers. By checking this box, i agree to receive updates, insights and offers from safetyculture and its affiliates by. Cooling log sheets date time temp time temp time temp time temp time temp time temp time temp 5 70 41 5 70 41 5 70 41 5 70 41 5 70 41 5 70 41 5 70 41. It is used within a maintenance contract to optimize system efficiency.

Prevent the release of odcs to the atmosphere by proper handling and disposal departmentperson responsible. The sintesis aircooled chillers are part of the ingersoll rand ecowise portfolio of products. Yk centrifugal chiller operating log sheets and maintenance requirements list form 160. Equipment containing ozone depleting chemicals odc purpose. To fully complete this form requires the outside air temperature to be 60 f or above unless a lower temp is allowed by oem. A tower designed for 85of and 3 gpmton, when given 2 gpmton, will return water at nearly 83of. Trane believes that responsible refrigerant practices are important to the. Cooling temperature log seminole county public schools. The names of the modules are linked to their functions. Trane is the only brand that supplies the entire package. Commissioning chilled water systems from design to. Touch this button to view the chiller operating mode screen.

Water cooled chiller with screw compressors water cooled chillers technical data ecoplus xe st cooling only c b a aircool mcquay reserves the right to make changes in design and construction at anytime without notice notes. Cool chiller price sheets use me mccormack distributing. This lower temperature will reduce the work requirement imposed on the chiller compressor and therefore reduce the energy consumption of the chiller. Ad related to refrigerant tracking log sheets log sheets bedsheets. Chiller log sheet fill online, printable, fillable. Basic information about chiller status and control appears on the face of the buttons and touch targets. Flow switch and water strainer are factory installed in the optimum locations for seamless operation and reduced chiller installation and maintenance time. Procedure daily weekly monthly yearly other record operating conditions on applicable log form x check refrigerant levels x check threephase voltage and current balance x. General cvhe and cvhg unit components overview cvhe, cvhg, cvhf each cvhe, cvhg, or cvhf unit is composed of 5 basic components. The original work order will be used to complete time sheets as usual.

When expanding chilled water plants, the same flow rate, cooling tower and. Chillers eliminate scale buildup, sewerage cost and tap water cooling expenses. Prior to chiller maintenance or repairs, contractor must contact the contract. Earthwise centravac watercooled liquid chillers trane. Oil analysis trane oil analysis is a predictive tool used to detect minor issues before they become major problems. Onesheet standard form used for recording all qpm on backup units, uploaded to sharepoint. To order a refractometer please call technical assistance at 253 7359466, these are also available from most propylene glycol suppliers. Trane cvhf installation, operation and maintenance manual 100 pages watercooled centravac chillers with tracer adaptiview control. Operators interface compressor report refrigerant report. Gha fc with ec fans air cooled chiller with screw compressors, axial fans and free cooling for outdoor installation energymiser gha b5a ec fc34 gha b140a ec fc34 gha b150a ec fc34 gha b160a ec fc34 gha b170a ec fc34 gha b180a ec fc34 chiller performance refrigerant r4a r4a r4a r4a r4a r4a. Trane ch530 with adaptive controls have improved fan algorithms for more reliable operation at extreme conditions.

Chiller status button the toplevel operating mode of the chiller appears on the chiller status button. Box 5024, hartford, york chiller maintenance checklist. Five 5 binary outputs are available on 0 5 dcv modules. Complete the chiller maintenance check with a digital signature. Stop key o pressing the stop key will send a request to the chiller to stop. Operation maintenance water cooled centravac with ch530. The mcsp is a compressor protection module with one being used for each of the compressors in the chiller.

Calculations use the specific chiller performance data provided by the individual manufacturers. Inspect the chiller area and its general condition and intended function. Page when considering selection of media other than water, contact the local trane sales office for chiller selections and factory performance testing information. Carbon steel tube sheets are drilled, reamed and grooved to. The frame supporting the unit is for positioning the unit with a crane or a forklift. These dualcompressor units feature two independent circuits, one for each compressor. Performance curves for more than 160 chillers, including the default doe2. Use the app to test flow rate, manage temperature of cooling towers, check for refrigerant leaks, energy efficiency and more.

Trane installation, operation and maintenance manual. Viewing the ashrae chiller log on the reports screen, touch ashrae chiller log to view the information that is itemized in ashrae chiller log. Operating status w 50th digit industrial chiller package indp 0 without indp w with indp 1 51st digit control power transformer cptr 0 without cptr 1 with cptr s special. Chiller equipment check sheet monthly quarterly form. Trane unit quarterly pm checklist linkedin slideshare. Centravac chiller has only one moving part a single rotating shaft supported. Rreelliiaabblleethe agility chiller has legendary trane reliability. Quick installation all series r chiller options, including control power transformer, starter disconnect, low ambient control, ambient temperature sensor, low ambient lockout, communication interface and ice making controls are factory installed and tested. Helicalrotary liquid chiller model rthc, 5501600 kw reliable sources of chilled water. It also reduces failure detection time and allows planning for appropriate maintenance.

Bp8202 16 oz cool chiller cups case bp8203 22 oz cool chiller cups case bp8204 32 oz cool chiller cups 720case bp8211 1622 oz lids case bp8212 32 oz lids case updated 21916 10. Please refer to the drawings provided with the chiller for chiller rigging details. Neither salt nor brackish water is recommend for use intrane aircooled cgam chillers. Keeping a chiller log sheet is advantageous as a preemptive chiller maintenance schedule can. Chiller selection assistance and performance information can be obtained by using the series r chiller selection program, available through local trane sales offices.

Weve developed our aircooled chillers with this intent in mind. The system evaluation manual and chiller evaluation. Allen pattillo aquaculture producers can use this downloadable and customizable excel spreadsheet to record fish feeding activity. The exv is the expansion valve controller module which controls two electronic expansion valves. Complete chiller system amp draw a refractometer should be used to obtain the actual glycol solution freeze point. Trane encourages employing a qualified water treatment specialist, familiar with local water conditions, to assist in establishing a proper water treatment program. Chiller system preventive maintenance check list inspectionreplacement items and frequency for technical support please contact pro refrigeration, inc. See auto led and diagnostic reset for further description. The system evaluation manual and chiller evaluation manual have been revised and combined into this new book. Current alarms announce and manual reset provision 2. See current trane service literature for more information. There is one valve on each of the two refrigeration circuits. Chiller maintenance and testing refrigerant charge.

An optional remote display is available to monitor unit operation from a remote location. If no other device or condition is preventing the chiller from starting and there is a need to cool, the chiller will attempt a start. Related searches refrigerant tracking sheets refrigerant log sheet forms refrigerant log sheet sample refrigerant record log sheet pdf refrigerant usage free log sheet refrigerant tracking. As basic as this may seem, having a daily record of operating conditions, the pressure and temperatures in the chiller unit, as well as the fluid levels and flow rate, could help quickly predict the likelihood of future damage to the chiller machine. Rtac 140500 ton units 60 hz read user manual online or download in pdf format. Continuous,extensive research and development,testing,and advanced manufacturing processes provide the most reliable compressor in.

The myplv tool provides no advantage to any one chiller type or manufacturer. The items included in the log sheet are those recommended by trane. Whole turkey, beef roast, pork roast and whole chicken or chicken pieces. This service will require trane technicians to remotely log onto the customers system.

It simply provides a bin analysis for the load profile and chiller performance entered by the program user. One 1 binary output and four 4 analog outputs are available on the 0 10 dcv modules. Controls, startup, operation, service and troubleshooting. T rane is a leading manufacturer of helicalrotary compressors. This ucmcld chiller control is composed of eight electronic modules, which each have their own 115v or 24v power supply and communicate with each other via a serial link. Chiller log sheet checklist download this checklist print as pdf anonymous. Most log sheets end up in a file on site,or in the companies office draw some of my important clients get chiller logs monthly,most quarterly,but i will still find time to photocopy them,and place them in a plastic file,stuck on the front of the chiller.

Riley tends to run low after site changes so his basal is decreased by 60% for 3. Principles of operation of the module ucmcld figure 1. Vwr chiller high cooling capacity microprocessor control in 0. Product catalog, aircooled scroll chillers, model cgam.

375 296 863 996 818 1184 1311 235 29 1211 1543 362 509 133 1373 937 611 71 968 769 738 69 1567 1125 1182 130 345 142 519 820 973 364 1576 1045 791 633 1533 474 1234 924 1026 1228 1196 422 440 645